Research Articles

IN-VITRO STUDY OF DIMENSION DIE STABILITY FOR LONG FIXED PROSTHESIS TAKEN BY PERFORATED METAL STOCK TRAYS AND SELF-CURING ACRYLIC TRAYS

Vol. 7 No. 12 (2011)
Published: 2014-01-19
Samuel David Giraldo Gómez
Elizabeth Pino Álvarez
Juan Sebastián Restrepo Luna
Luisa Fernanda Quiceno Bedoya

Introduction: taking fixed partial denture impressions, silicon is better by adding dimension stability and a higher detail reproduction. Trays are required; they may be perforated metal stock or self-curing acrylic. Materials and

methods: we performed an experimental, comparative in-vitro study by sampling 10 plaster models got from ten impressions taken using five perforated metal stock trays and five self-curing acrylic trays, all of them made by stainless steel model simulating the lower jaw. Measuring plaster models and the stainless steel model was performed by a single operator through a stereoscope Nikon model CPs 160, Series 1005941. First, we calibrated the stainless steel model by measuring height and diameter of abutment teeth canines 33-43, first molars 36-46, the interpillar distance between 33-43 and 43-46. Then plaster models were measured and results compared using descriptive summary measures and averages based on Mann-Whitney test.

Results: none of the measurements taken on models based on both basin types revealed a statistically significant difference p > 0.5.

Conclusions: no statistically significant difference by taking impressions with perforated metal stock trays or self-curing acrylic trays.

Keywords: Array, Array, Array

How to Cite

IN-VITRO STUDY OF DIMENSION DIE STABILITY FOR LONG FIXED PROSTHESIS TAKEN BY PERFORATED METAL STOCK TRAYS AND SELF-CURING ACRYLIC TRAYS. (2014). Revista Nacional de Odontología, 7(12), 35-42. https://revistas.ucc.edu.co/index.php/od/article/view/297

Shillingburg HT, Hobo S, Whitsett L, Jacobi R, Brackett S. Fundamentals of fixed prosthodontics. 1997; 1-582. 2006. Quintessence Publishing.Ref Type: Serial (Book,Monograph).

Thongthammachat S, Moore BK, Barco MT 2nd, Hovijitra S, Browwn DT, Andres CJ. Dimensional accuracy of dental cast: influence of tray material, and time. J. Prosthodont. 2002; 11(2): 98-108.

Boulton JL, Gage JP, Vincent PF, Basford KE. A laboratory study of dimensional changes for three elastomeric impression materials using custom and stock trays. Aust Dent J. 1996; 41(6): 398-404.

Dykema R. GCyPR. Johnston’s modern practice in fixed prosthodontics. Philadelphya: Saunders; 1986.

Donovan TE, Chee WW. A review of contemporary impression materials and techniques. Dent Clin N Am 48. 2004 445-470.

Anusavice K. Phillips´Ciencia de los materiales dentales. USA: W.B Saunders; 1996.

Rupp F, Axmann D, Jacobi A, Groten M, Geis-Gerstorfer J. Hydrophilicity of elastomeric non-aqueous impression materials during setting. Dent Mater. 2005; 21(2): 94-102.

Wassell RW, Ibbetson RJ. The accuracy of polyvinyl siloxane impressions made with standard and reinforced stock trays. J Prosthet Dent. 1991; 65(6): 748-57.

Klooster J, Logan GI, Tjan AH. Effects of strain rate on the behavior of elastomeric impression. J Prosthet Dent. 1991; 66(3): 292-8.

Carrotte PV, Johnson A, Winstanley RB. The influence of the impression tray on the accuracy of impressions for crown and bridge work --an investigation and review. Br Dent J. 1998; 185(11-12): 580-5.

Millstein P, Maya A, Segura C. Determining the accuracy of stock and custom tray impression/casts. J Oral Rehabil. 1998; 25(8): 645-8.

Rehberg HJ. The impression tray --an important factor in impression precision. Int Dent J. 1977; 27(2): 146-53.

McGiney GP, Castleberry DJM. Prótesis Parcial Removible. Buenos Aires: Ed Médica Panamericana; 1989.

Echeverria P, Roldan M. Rehabilitación del paciente edentado. Medellín: Universidad de Antioquia; 1997.

Tjan AH, Nemetz H, Nguyen LT, Contino R. Effect of tray space on the accuracy of monophasic polyvinylsiloxane impressions. J Prosthet Dent. 1992; 68(1): 19-28.

Gordon GE, Johnson GH, Drennon DG. The effect of tray selection on the accuracy of elastomeric impression materials. J Prosthet Dent. 1990; 63(1): 12-5.

Boulton JL, Gage JP, Vincent PF, Basford KE. A laboratory study of dimensional changes for three elastomeric impression materials using custom and stock trays. Aust Dent J. 1996; 41(6): 398-404.

MÉTRICAS
ARTICLE VIEWS: 1963
PDF VIEWS: 1406

Most read articles by the same author(s)