• Investigación

    Air Measurement in Residential Hydrometer: Preliminary Results

    Vol. 12 No. 19 (2016)
    Published: 2016-04-01
    Vinicus Grando Sirtoli
    Universidade do Estado de Santa Catarina
    Airton Akio Watabe Sato
    Universidade do Estado de Santa Catarina
    Pedro Bertemes Filho
    Universidade do Estado de Santa Catarina

    Introduction: This article was created by the 2015research for the Electronics’ Engineering Degree of the University of Santa Catarina’s department (Brazil). Most systems that measure water and are used in residences can register the air flow that may be present in the distribution system. This problem is hard to measure, since it’s a combination of liquid and gas. The purpose of this article is to identify and quantify the sensibility of residential hydrometers to the air volume registered.

    Methodology: To accomplish it, an experimental hydraulic circuit was developed, and sensors were deployed to monitor the water entry and exit of the system, composed by two warehouses. One warehouse stored water for the circulation of the hydraulic drainage, while the other stored the total amount of water in the system. The water level in the storehouses is controlled with ultrasonic and potentiometer sensors. A spinner is used to estimate the total water volume that enters the system by measuring its volumetric flow.

    Results: The results show that the hydrometer is very sensible to the air flow and that it can measure up to 44% of air in the air/water combination. The difference in the estimated water volume in the spinner and in the hydrometer was of 3,7 liters.

    Conclusions: The hydrometer is especially sensible to air presence in the residential hydraulic pipelines under normal conditions of a nominal flow of approximately 1,5 m3 /h.

    Keywords: hydraulic circuit, hydrometer, electronic instrumentation, air/water combination, spinner

    How to Cite

    [1]
    V. G. Sirtoli, A. A. Watabe Sato, and P. Bertemes Filho, “Air Measurement in Residential Hydrometer: Preliminary Results”, ing. Solidar, vol. 12, no. 19, pp. 73–79, Apr. 2016, doi: 10.16925/in.v12i19.1195.

    I. S. L. Miranda, F. C. Tonial, J. C. Kuritiza e M. G. Marques, “Presença de Ar no Sistema de Abastecimento de Água: Influências no Funcionamento de Hidrôme-tros”. Simpósio Brasileiro de Recursos Hídricos, Bento Gonçalves, nov., 2013, p. 17-22. Disponível: https://www.abrh.org.br/SGCv3/UserFiles/Sumarios/6b5acb09a6f7970b7710773bfcfc8b31_86712b6a2927dd4d9398884e4692b3ee.pdf

    M. A. Garcia, “Análise do desempenho em campo de hidrômetros Qn 0,75 m³/h”, 39ª Assembleia Nacional da ASSAMAE, Gramado. Anais eletrônicos, Brasília: AS-SEMAE. 2009, 10p.

    M. T. Tsutiya, “Abastecimento de Água”. São Paulo: Departamento de Engenharia Hidráulica e Sanitária da Escola Politécnica da Universidade de São Paulo, 3ª ed., 643 p.

    G. Brito e P. Silva Junior. “Brasil: Estado mais importante do país sofre crise hídri-ca”. Correio da Cidadania, jan., 2015. Disponível: http://cartamaior.com.br/?/Editoria/Cidades/Brasil-Estado-mais-importante-do-pais-sofre-crise-hidrica/38/32762.

    FALVEY, H.T, “Air-water Flow in Hydraulic Structures.” USBR Eng. Monogra-phy, No. 41, Denver, Colorado, USA, 1980. Disponível: http://www.arlis.org/docs/vol2/hydropower/APA_DOC_no._899.pdf

    N. P. Lopes, M. Lara, M. Libânio, “Quantificação em Escala de Bancada do Volume de Ar em Ligações Prediais de Água”. Engenharia Sanitária Ambiental, v. 16, n. 4, nov., 2011, p. 343-352. doi: http://dx.doi.org/10.1590/S1413-41522011000400005

    R. S. D. Souza, M. Polizer, M. A. C. Rondon, L. A. A. D. VAL, J. Gonda, “Avalia-ção da influência de um equipamento eliminador de ar na medição de consumo de água numa rede de distribuição”. 23º Congresso Brasileiro de Engenharia Sanitária e Ambiental, Campo Grande. Anais Abes, 2005, p. 1-11. Disponível: http://www.mediafire.com/view/l1mmnywtom2/I-063_avaliacao+eliminadores.pdf

    F. C. T. Leal, J. C. Teixeira, “Avaliação da eficácia e da possibilidade da contamina-ção da água em eliminadores de ar fabricados em polipropileno, quando instalados em cavaletes de ligações de água potável - estudo de caso: Juiz de Fora – MG”. Congresso Brasileiro de Engenharia Sanitária e Ambiental. Rio de Janeiro, v. 9, n. 3, set., 2004, p. 187-192. Disponível: http://www.scielo.br/scielo.php?pid=S1413-41522004000300003&script=sci_arttext

    E. J. Mello, R. L. Farias, “O ar e sua influência na medição do consumo de água”. 23º 21º Congresso Brasileiro de Engenharia Sanitária e Ambiental. João Pessoa, 2001. Disponível: http://www.mediafire.com/view/gm1jettmht4/i-001ar.pdf

    INMETRO - Instituto Nacional de Metrologia, Normalização e Qualidade Industri-al, 2000. Ministério do desenvolvimento, indústria e comércio. Portaria n.° 246, 17 de outubro de 2000.

    P. S. Scalize e W. C. A. Leite, “Variação da Micromedição do consumo de Água no Funcionamento Correto e Reversível do Hidrômetro”. Revista Eletrônica de En-genharia Civil, v. 6, n. 1, 2013. Disponível: http://revistas.ufg.br/index.php/reec/article/view/21240/13102

    I. S. L. Miranda, “Presença de ar no sistema de abastecimento de água: Influências na macro e micromedição”. TCC, Universidade Federal do Rio Grande do Sul, Por-to Alegre, 2011. Disponível: http://www.lume.ufrgs.br/bitstream/handle/10183/34404/000789709.pdf?sequence=1&locale=pt_BR.

    MÉTRICAS
    ARTICLE VIEWS: 827
    PDF VIEWS: 1308
    Metrics
    Metrics Loading ...
    https://plu.mx/plum/a/?doi=10.16925/in.v12i19.1195