Investigación

Use of Reversed-Phase hplc for the Determination of Free Formaldehyde Content in Nail Polishes

Vol. 13 No. 22 (2017)
Published: 01-05-2017
María Maldonado Santoyo
Erika Hernández Guerrero
Gladys Morales López
Javier Antonio Arcibar Orozco
Juliette Alexandra Lambert
Jennifer Alexis Bañuelos Díaz

 Introduction: This article derives from the research titled Use of reversed-phase hplc for the determination of free formaldehyde content in nail polishes, conducted in 2015 at the Center for Applied Innovation in Competitive Technologies (ciatec).

Method: The free formaldehyde content was determined in 50 samples of nail polishes of various brands marketed in León, Guanajuato, Mexico. Samples were treated according to the iso 17226-1:2003 method, with slight modifications: 2 ± 0.1 g of nail polishes were weighed in 100 ml Erlenmeyer flasks, 40 ml of 0.1 % sodium dodecyl sulfonate were added; the samples were then capped and left in a water bath at 40 °C under constant stirring for 60 minutes; they were subsequently filtered, and aliquots of each sample were taken for derivatization with 0.3 % 2,4-dinitrophenylhydrazine for 60 minutes. The analytical determination was achieved by reversed-phase hplc-diode array detection.

Results: All nail polish samples tested were below the regulatory limit of 0.2 % free formaldehyde content in cosmetics.

Conclusions: We obtained toxicologically relevant information on free formaldehyde in nail polishes, in addition to checking the versatility and robustness of the test method. 

Keywords: Array, Array, Array, Array

How to Cite

[1]
M. Maldonado Santoyo, E. Hernández Guerrero, G. Morales López, J. A. Arcibar Orozco, J. A. Lambert, and J. A. Bañuelos Díaz, “Use of Reversed-Phase hplc for the Determination of Free Formaldehyde Content in Nail Polishes”, ing. Solidar, vol. 13, no. 22, pp. 27–37, May 2017, doi: 10.16925/in.v13i22.1750.

N. G. Yasri, H. Seddik & M. A. Mosalb, “Spectropho-tometric determination of formaldehyde based on the telomerization reaction of tryptamine”, Arabian Journal of Chemistry, vol. 8, n.o 4, pp. 487-494. 2011. doi: https://doi.org/10.1016/j.arabjc.2011.02.005

Organización Mundial de la Salud, “Formaldehído: Guía para la salud y la seguridad”, Programa Interna-cional de Seguridad de las Sustancias Químicas, n.o 57, pp. 2-17, 1995. Disponible en: http://www.bvsde.paho.org/ bvsacd/eco/030511.pdf

Food and Drug Administration. mlm Law: fda Cosmetics Handbook. Disponible en: http://www.ml-mlaw.com/library/guides/fda/Coshdbok.htm

X. Xu, R. Su, X. Zhao, Z. Liu, D. Li, X. Li, et al., “De-termination of formaldehyde in beverages using mi-crowave-assisted derivatization and ionic liquid-based dispersive liquid-liquid microextraction followed by high-performance liquid chromatography”, Ta-lanta, vol. 85. pp. 2632-2638, 2011. Disponible en: http://www.sciencedirect.com/science/article/pii/S0039914011007569

L. Chen, H. Jin, L. Wang, L. Sun, H. Xu, L. Ding et al., “Dynamic ultrasound-assisted extraction cou-pled on-line with solid support derivatization and high performance liquid chromatography for the determination of formaldehyde in textiles”, Journal of Chromatographya, vol. 11, n.o 92, pp. 89-94, 2008. doi: 10.1016/j.chroma.2008.03.037

R. T. Rivero & V. Topiwala, “Quantitative determina-tion of formaldehyde in cosmetics using a combined solid-phase microextractión-isotope dilutión mass spectrometry method”, Journal of Chromatography A., vol. 1029, pp. 217-222, 2004. doi: https://doi.or-g/10.1016/j.chroma.2003.12.054

E. T. Martínez-Espinoza, G. Morales-López, J. J. N. Segoviano-Garfías & M. Maldonado-Santoyo, “De-termination of formaldehyde content in footwear samples using a hplc-uv technique”, International Journal of Scientific and Research Publications, vol. 5, n. º 11, pp. 225-229, 2015. Disponible en: http://www.ijsrp.org/research-paper-1115.php?rp=P474780

Ch. Lv, J. Sun & H. Cheng, “Determination of formal-dehyde residue in cosmetics by short-column high performance liquid chromatography with mass spec-trometric confirmatión”, Analytical Methods, vol. 7, pp. 1630-1634, 2015. doi: https://doi.org/10.1039/C4AY02546F

M. Gandhimathi, M. Jagadeeswaran & T. K. Ravi, “Evaluation of select cosmetic preparations for the presence of formaldehyde and methyl paraben by novel analytical methods”, Indo American Journal of Pharmaceutical Research, vol. 3, n.o 8, pp. 6477-6483, 2013. Disponible en: http://www.scopemed.org/full-tex tpdf.php?mno=154151

Y. Vander-Heyden, A. Nguyen Minh-Nguyet, M. R. Detaevernier, D. L. Massart & J. Plaizier-Vercam-men, “Simultaneous determination of ketoconazole and formaldehyde in shampoo: liquid chromatogra-phy method development and validation”, Journal of Chromatography A, vol. 958, pp. 191-201, 2002. doi: https://doi.org/10.1016/S0021-9673(02)00384-9

H. Wang, J. Ding, X. Du, L. Chen, Q. Zeng, Y. Xu, et al., “Determination of formaldehide in fruit jui-ce based on magnetic strong cation-exchange resin modified with 2,4-dinitrophenylhydrazine”, Food Chemistry, vol. 131, pp. 380-385, 2012. doi: https://doi.org/10.1016/j.foodchem.2011.08.056

R. J. Elías, V. F. Laurie, S. E. Ebeler, J. W. Wong & A. L. Waterhouse, “Analysis of select carbonyl oxi-dation products in wine by liquid chromatogra-phy with diode array detection”, Analytica Chimica Acta, vol. 626, pp. 104-110, 2008. doi: https://doi.org/10.1016/j.aca.2008.07.048

S. M. Ochs, M. Fasciotti, R. P. Barreto, N. G. de Figueiredo, F. C. Albuquerque, M.C.G. Pontes-Mas-sa et al., “Optimization and comparison of hplc and rrlc conditions for the analysis of carbonyl-dnfhderivatives”, Ta l a n t a, vol. 81, pp. 521-529, 2010. doi: 10.1016/j.talanta.2009.12.036

S. Uchiyama, Y. Inaba & N. Kunugita, “Derivatiza-tion of carbonyl compounds with 2,4-dinitrophen-ylhydrazine and their subsequent determination by high-performance liquid chromatography”, Journal of Chromatography B, vol. 879, pp. 1282-1289, 2011. Disponible en: http://www.sciencedirect.com/scien-ce/ article/pii/S157002321000615X

D. Bourdin & V. Desauziers, “Development of spmeon fiber derivatization for the sampling of formal-dehyde and other carbonyl compounds in indoor air”, Anal Bioanal Chem, vol. 406, pp. 317-328, 2014. Disponible en: http://link.springer.com/arti-cle/10.1007%2Fs00216-013-7460-6

iso, “Method iso/ts 17226:2003 (e): Leather chemi-cal test determinatión of formaldehide content”, 1aedición, pp. 1-9, 2003. Disponible en: http://www.iso.org/iso/iso_catalogue/catalogue_ics/catalogue_detail_ics.htm?csnumber=31292

us-epa, “Method 8315a: Determination of carbonyl compounds by high performance liquid chromatography (hplc)”, Revisión 1. pp. 1-34, 1996.

W. Pai-Wen, Ch. Chieu-Chen & Ch. Shin-Shou, “Determination of formaldehyde in cosmetics by hplc method and acetylacetone method, Journall of food and drug analysis, vol. 11, n.º 1, pp. 8-15, 2003. Disponible en: http://www.fda.gov.tw/tc/includes/GetFile.ashx?mID=148&id=7474&chk=7bc32085-c406-4b65-9964-93fba5e966b8.

J. M. Storey, W. C. Andersen, A. Heise, S. B. Turnipseed, J. Lohne, T. Thomas et al., “A rapid liquid chrmatog-raphy determinatión of free formaldehyde in cod”. Journal Food additives and contaminants: Part A, vol. 32, nº 5, pp. 657-664, 2015. doi: http://dx.doi.org/10.1080/19440049.2015.1020530

A. Soman, Y. Qiu & Q. Chan-Li, “hplc-uv method development and validation for the determination of low level formaldehyde in a drug substance”, Jour-nal of Chromatographic Science, vol. 46, pp. 461-465, 2008. Disponible en: http://chromsci.oxfordjour-nals.org/content/46/6/461.full.pdf

Iris National Acreditation Board, “PS15: Guide to method validation for quantitative analysis in chemical testing laboratories (iso 17025)”, n.º 4, pp. 1-27, 2016. Disponible en: http://www.inab.ie/Documents-Forms/Policy/Guide-to-Method-Vali-dation-for-Quantitative-Analysis-in-Chemical-Test-ing-Laboratories-17025-PDF-36-Pages-349KB-.pdf

A. Nageswari & K. V. S. R. Krishna Reddy, “Low-lev-el quantification of formaldehyde in drug substance by hplc-uv, Chromatographia, vol. 75, pp. 275-280, 2012. Disponible en: http://link.springer.com/arti-cle/10.1007/s10337-012-2186-8

cenam & ema, Guía técnica sobre trazabilidad e in-certidumbre en las mediciones analíticas que emplean las técnicas de cromatografía de gases (cg) y cromato-grafía de líquidos de alta resolución (clar), México, 2008.

J. S. Herrington & M. D. Hays, “Concerns regard-ing 24-h sampling for formaldehyde, acetaldehyde, and acrolein using 2,4-dinitrophenylhydrazine (dnfh) coated solid sorbentes”, Atmospheric Envi-ronment, vol. 55, pp. 179-184, 2012. doi: https://doi.org/10.1016/j.atmosenv.2012.02.088

us-epa, Method 8000C:Determinative chromato-graphic separations. Revisión 3, pp. 1-66, 2003. Disponible en: http://www.caslab.com/EPA-Methods/PDF/EPA-Method-8000C.pdf

H. Engelhardt & R. Klinkner, “Determination of free formaldehyde in presence of donators in cosmetics by hplc and post-column derivation”, Chromato-graphia, vol. 20, n.º 9, pp. 559-565, 1985.

MÉTRICAS
ARTICLE VIEWS: 1503
PDF VIEWS: 719